From: route@monster.com
Sent: Wednesday, August 10, 2016 8:09 AM
To: hg@apeironinc.com
Subject: Please review this candidate for: Safety Coordinator
This resume has been forwarded to
you at the request of Monster User xapeix03
|
|||||||
|
|||||||
|
|
|
||||||
|
||||||
|
ERIC D. DAVIS 1797 SHERBROOKE STREET SAN DIEGO, CA. 92139 edavisinc@yahoo.com C - (619) 750-2275 OBJECTIVE:
Electronics Technician BACKGROUND SUMMARY: Dedicated Professional with
over 15 years experience. Proven background in lab and field experience
including testing, troubleshooting, installation, calibrating, and
documentation, and coordination of various products utilizing laboratory
equipment. Hard working individual, motivated to perform tasks in
an accurate and timely manner. EXPERIENCE: 10/13- PresentHewlett Packard through National
Technical Services (NTS), San Diego, CA Product Safety Test Technician Conducts electrical testing of power supplies,
motors and end-use products to ensure the technology complies with
regulations of Safety Standards IEC/UL 60901. Complies test data from
performed testing to generate reports and reviews results with
engineers. Perform Qualification, Safety Agency and Design Verification
Testing for new existing products. Setting up, operating, and maintaining the
test equipment used in safety testing. Check calibration stickers and
calibration certificates of Safety Engineering equipment in accordance with
UL standards. 6/12 – 10/13 Aquaneering Inc.,
San Diego, CA Electrical Technician/ Lead Person Building electrical equipment such as Control
Boxes, Time-Water Exchanges and UV Ballast Box. Also building Water
Monitoring System using Web-600, Sensaphone SCADA, Signet Meters and
Aquatouch using Electrical drawings, diagrams and verbal instructions. Wiring
up and Installing Motors, Pumps, Heaters and Outlets that are installed in
Aqua-Cultural Fish Testing Systems used by Disease Research Centers,
Hospitals and Universities. Also I was responsible for purchasing all
electronic, electrical and mechanical components / parts for current &
upcoming builds as well as maintaining a suitable stock level. 9/11-6/12 Carefusion thru/ Adecco, San Diego,
CA Biomed Field Service Technician Visiting Hospitals in the US performing
Upgrades/Remediation/Service Calls on a Avea Ventilators Machines.
Removing/Replacing TCA( Transducer Communication Alarms) Boards, Epm (Enhance
Patient Monitoring)
Boards & Troubleshooting down to component level. Performing New
calibrations on Transducers and conducting OVP (Operational Verification
Procedure) on unit. Record documentations/records of upgrades/remediation of
each unit. Use standard hand tools to open electronic devices, disassembles
and reassembles unit. Practiced strict ESD protection procedures. 6/10 – 9/11 SouthBay Expressway, San Diego, CA Field Service Technician Duties included corrective and preventive
maintenance to the SCADA Toll system, maintain hardware software and
electrical equipment, components, and system devices of the SBX Fixed
Operating Equipment (FOE) including the Traffic Management System (TMS),
Surveillance and Access Control System (SAC), and the Toll Collection System (TCS)
according to full coverage and on-call response/repair time deadlines,
operate and maintain bucket truck. Update the FOE SBX e-mail when
performing trouble calls during normal and after hours support. Other duties
included the planning and oversight of road closures for emergency,
corrective maintenance, planned maintenance and other improvements.
Administrative duties included documentation of work orders and inventory
tracking, coordination of repairs with third party vendors, and the
justification and purchase of new equipment 7/08 – 6/10Lee Maintenance & Janitorial
Service, After I was laid off from Cubic, I replaced my
mother in the family business. She had to have surgeries on both hands to
correct Carpal Tunnel. I cleaned buildings for 23 months. 9/05 – 7/08 Cubic Defense
Corporation, San Diego, CA Electronic Technician Duties: Developed test process and
procedures that are used for CDLS Data Link Systems operating within
different frequencies of KU and X wideband for the transmission of
intelligence data. Provided leadership and technical expertise in the analysis,
testing, and debugging of analog and RF systems which consists of various
drawers and racks. Tested various military training hardware such
as AT4s and MILES 2000 gear. Also tested different types of cables such as
Fiber Optics, Telecom and custom Cables used to connect the CDLS Data Link
System. Skilled in other Environmental testing such as ESD, Burn-In
Test, Non-Op-Magnetic, and Shock & Vibe, Thermal Cycling Chambers. Help
provide failure analyses on prototypes when they did not meet specs. 9/03 – 09/05 TUV America Inc., San Diego,
CA Compliance Test Engineer Duties: Responsible for Electrical Safety
testing, such as, circuit breakers, ground fault systems , Power Supplies,
inspecting products for conformity assessment with International Regulations
with the end result being a certificate of conformance, technical report, or
test report for the client. Prepared CB reports and documentation for
certification of customer products to the appropriate agencies such as UL,
CSA and VDE. Also Coordinated laboratory activities by testing, preparing
data sheets and instructions to technicians, scheduled, reviewed, and
established completion dates of work for laboratory and engineering support
staff. Coordinate/perform all lab equipment calibrations and test fixtures
verification per OSHA requirements. 6/02 – 7/03 Phogenix Imaging/thru Kelly
Services, San Diego, CA Manufacturing Technician Duties: Troubleshooting and Maintaining Digital
Photo Printers/Systems mechanically- electronically. Installing, repairing, rebuilding
and testing various printer subsystems. Insure all related paperwork is complete for work
performed on ECO’s (Engineering Change Orders). Building SDMs (System Data
Manager) installing Workstations, Hard-drives ,Memory, Zip-Drives and other
computer accessories as part of the options package. Conducts verification testing of
lab equipment, also downloading of new firmware and code and installing end-users
software. In addition, assist QA with setup & test functions, which include performing
PVT (Product Verification Testing). 7/98 - 4/02 Underwriters Laboratories Inc.,
San Diego, CA Engineering Associate Duties: Manage and execute timely completion of
basic Electrical Safety Testing of Power Supplies and other
equipment/components by analyzing project scope and determining project
specifications, establishing test programs for product investigations,
analyzing test programs for adequacy and sequence, examining clients’ samples
for compliance with UL requirements, and preparing UL reports also
troubleshooting failure analyses on electronic or electro-mechanical
devices/products to give feed back to customers when products did not meet UL
requirements. Developed a preliminary plan of investigation and
determines project specifications such as cost, time and sample requirements
by analyzing client input, available supplemental data, and product
constructions. Coordinated laboratory activities by preparing
data sheets and instructions to technicians, scheduled, reviewed, and
established completion dates of work for laboratory technicians and
engineering support staff. Established the Regulatory Lab for the UL San
Diego office. Responsible for purchasing all necessary lab equipment/meters
and software to perform the entire gamut of safety testing from prototypes to
certifications. 9/94 - 7/98 Hewlett-Packard, Rancho
Bernardo, CA. Technician Duties: Under general supervision, assists in the
design, layout, testing and evaluation of electronics or electro-mechanical
devices or systems used in the All In One product line. Responsible for
regulatory testing on different types of electronics/electro-mechanical
components, including Power Supplies that were used in the research and
development of All In One fax machine. Testing was completed utilizing
specialized test equipment that met the requirements of various applicable
Regulatory Standards. Final tests results and reports were generated in the
presence of a Safety Engineer from one of the various Regulatory Agencies
(UL, TUV, Nemko, CSA) using word processors and spreadsheets with graphics
capabilities. Also skilled in other Environmental testing such
as Package Drop, ESD, Burn-In Test, Non-Op-Magnetic, and Shock & Vibe,
Thermal Cycling Chambers. Help provide failure analyses on prototypes when
they did not meet HP specs. Established the Regulatory Lab for HID
Division. Responsible for purchasing all necessary test equipment and
software to perform the entire gamut of regulatory testing from prototypes to
final products that were used to obtain different regulatory
marks.
SKILLS:
Automation Electronics Programmable
Logic Control (PLC) R.F. Communications Computer
Numerical Control Digital Systems Hydraulics
and Pneumatics DMMs, O’scopes &
various meters
Programming Software
C, Pascal
MS Office, HP VEE, Labview Specialty Courses: Time Management Made Easy Problem Solving / Decision Making Water Treatment I Electrical & Instrumentation Controls EDUCATION: ITT Technical Institute GPA: 3.2 Bachelor of Applied Science Automated Manufacturing Technology, March 1993 ITT
Technical Institute GPA: 3.2 Associate of Applied Science Electronics Engineering Technology, March 1992 PERSONAL: Self-Motivated, hard working, quick
learner, dedicated to performing the job task with little or no supervision. |
|
|
||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Languages: |
Languages |
Proficiency Level |
|
English |
Fluent |
|
|
|